DSV Inlet D01 Stealth

D01 Inlet platform. Stealth top profile, direct, load-stable piston actuation.

DSV Inlet D01 Stealth DSV Inlet D01 Stealth DSV Inlet D01 Stealth

Inside the D01 Inlet architecture.

Direct piston command with three clearly defined flow levels.

Plus First Generation Piston Dark

Direct feed. Defined tactile response. Progressive airflow.

DRYSUIT SYSTEMS · INFLATION VALVES

The D01 Inlet Series is built around a compact 35 mm low-profile button with activation-safe design, based on a First-Generation Piston Architecture.

Direct, load-stable actuation and a firm mechanical break point support higher command fidelity across the usable stroke, while airflow develops through a smooth three-level ramp from 150 to 275 L/min.

A 360° swivel with stop keeps routing clean and torsion controlled within a compact, low-bulk Inflation platform.

First-Gen Piston. Stable Feed Response. First-Generation Piston Architecture gives D01 Inflation a direct mechanical command path through the usable stroke. The firm break point supports clear actuation feedback, while airflow builds across three controlled levels from 150 to 275 L/min.

D01 Inflation core features, built around compact integration, controlled Inflation response, and stable actuation.

First-Generation

PISTON ARCHITECTURE

First-Generation Piston Architecture. Direct, load-stable actuation with a firm mechanical break point.

First-Generation Piston Architecture. Direct, load-stable actuation with a firm mechanical break point.

Improved command fidelity across the usable stroke.

Improved command fidelity across the usable stroke.

Inflation Range & Progression mapped through the stroke with two flow levels.

Inflation Range & Progression
mapped through the stroke with three flow levels.

360° SWIVEL WITH STOP

Near 360° swivel with stop for clean routing and controlled torsion.

Near 360° swivel with stop for clean routing and controlled torsion.

LOW PROFILE

BUTTON INTERFACE

35 mm / 1.38 in

35 mm / 1.38 in

Stealth

TOP PROFILE

Durable, Reinforced structure, Pentago-shape design.

Durable, reinforced structure. Pentagonal design.

Engineered for broad drysuit integration across modern port cutouts worldwide, with S-FIT / L-FIT configurations for clean, repeatable fit.

Engineered for broad drysuit integration

across established port standards,

with S-FIT / L-FIT configurations for clean, repeatable mounting

Port Fit

Configured for 34 mm (1.34 in) drysuit port openings.

Each HYDPRO device is engineered and manufactured in Italy: one chain from raw material to release. Polymer families are selected for constant immersion, precision-drawn brass runs on in-house CNC lines, and every device leaves built, tested, and signed off under one roof.

Whatever the field runs, HYDPRO builds to it natively: every established mount standard, thread, and host geometry, covered from the factory. Your setup stays as it is, integration stays clean, and the response repeats: the same command, the same result, on every dive.

DSV Inlet D01 Stealth
DSV Inlet D01 Stealth

D01 Inlet platform. Stealth top profile, direct, load-stable piston actuation.

DSV Inlet D01 Stealth

HYDPRO Underwater Air Management devices across inflator, drysuit, hose, and pressure-relief systems: built to upgrade your dive setup with controlled integration, consistent response, and cleaner equipment architecture.

Buy now Buy now

Compare products

HYDPRO Power J01 K-Style inflator side view with K-profile body

J01 Series Core. HYDPRO K-profile, open geometry.

Learn more
HYDPRO Power J01 Raw inflator side view with squared-off monobloc body

J01 Series Core. Squared-off monobloc body, closed geometry

Learn more
HYDPRO Power Q01 Code inflator side view with forged Code body geometry

Q01 Series Core. Robust proportions, open geometry.

Learn more
IDENTITY
Series
J01
J01
Q01
Compatibility
Fits T23 and T25 corrugated hoses
Fits T23 and T25 corrugated hoses
Fits T23 and T25 corrugated hoses
Application
BCD and wing buoyancy control
BCD and wing buoyancy control
BCD and wing buoyancy control
Range
Tek
Tek
Tek
Variant
K-Style
Raw
Code
External body geometry
Established K-profile, open geometry.
Squared-off monobloc body, closed geometry.
Robust proportions, open geometry.
SIZE & WEIGHT
Overall height
78.1 mm / 3.07 in
78.6 mm / 3.09 in
78.6 mm / 3.09 in
Overall width
69.4 mm / 2.73 in
66.5 mm / 2.62 in
70.1 mm / 2.76 in
Overall depth
26 mm / 1.02 in
27.8 mm / 1.09 in
26.8 mm / 1.06 in
Weight
Metal = 136.4 g / 4.81 oz
Technopolymer = 79.9 g / 2.82 oz
Non-Magnetic = 76.9 g / 2.71 oz
Metal = 135.5 g / 4.78 oz
Technopolymer = 80.1 g / 2.83 oz
Non-Magnetic = 77.1 g / 2.72 oz
Metal = 160.7 g / 5.67 oz
Technopolymer = 97 g / 3.42 oz
Non-Magnetic = 94 g / 3.32 oz
COUPLING & INTERFACE
Mount standard
T23 (23.6 mm / 0.93 in)
T25 (25.4 mm / 1.00 in)
T23 (23.6 mm / 0.93 in)
T25 (25.4 mm / 1.00 in)
T23 (23.6 mm / 0.93 in)
T25 (25.4 mm / 1.00 in)
PERFORMANCE & BUILD
Command interface
Round Touch
Round Touch
Round Touch
Inflate button diameter
22 mm / 0.87 in
22 mm / 0.87 in
25 mm / 0.98 in
Exhaust button diameter
22 mm / 0.87 in
22 mm / 0.87 in
25 mm / 0.98 in
Inflation architecture
Piston — Second Generation
Piston — Second Generation
Piston — Second Generation
Inflate button actuation force
3.2 kgf / 7.05 lbf
3.2 kgf / 7.05 lbf
2.1 kgf / 4.63 lbf
Second-stage actuation force
4 kgf / 8.82 lbf
Maximum extended-stage inflation flow
350 L/min / 12.36 SCFM
Inflation flow rate — range & progression
65–285 L/min across 4 progressive levels
65–285 L/min across 4 progressive levels
65–275 L/min across 4 progressive levels
+ Q-Shift HI-FLOW: 350 L/min second stage
Flow Ramp
Edge Lock System
Q-Shift
Exhaust architecture
Driven Seal
Driven Seal
Driven Seal
Exhaust button actuation force
3.18 kgf / 7.01 lbf
3.18 kgf / 7.01 lbf
3.2 kgf / 7.05 lbf
Exhaust flow rate — range & progression
60–350 L/min across 4 progressive levels
60–350 L/min across 4 progressive levels
60–350 L/min across 4 progressive levels
Actuation core
Metal
Technopolymer
Non-Magnetic
Metal
Technopolymer
Non-Magnetic
Metal
Technopolymer
Non-Magnetic
CONFIGURATION
Configuration options
Metal, Technopolymer and Non-Magnetic actuation configurations
Metal, Technopolymer and Non-Magnetic actuation configurations
Metal, Technopolymer and Non-Magnetic actuation configurations